Mustang® Sample Conditioning System

The Mustang® Sample Conditioning System (MSCS) provides an Analytically Accurate® solution for natural gas sampling applications.

The Mustang® P53 and the Mustang Pony® Probe Enclosure are integral parts of the MSCS. The Mustang Pony Probe Enclosure is installed on to a threadolet in proximity to the Mustang P53.

The MSCS solves the problem of hydrocarbon liquid condensation from Joule-Thomson cooling in natural gas analysis systems.  High pressure natural gas samples are transported at a temperature well above the expected hydrocarbon dew point, which is maintained throughout the pressure reduction process, delivering a representative sample to the analyzers.

Features

  • Patented technology utilizing existing power supplied by electric heat trace tube bundle
  • Remote Mounted
  • Rated for Class 1, Division 1, Group D locations
  • Steel latching closures

Benefits

  • Requires no external power or natural gas for proper operation
  • Conforms to the API Manual of Petroleum Measurement Standards chapter 14.1

Certifications

  • cETLus Certified

Specifications

Wetted Parts 316 SS
Mustang® P53 Maintains Sample Gas Standard set point at 120ºF (49ºC)
Adjustable from 60-400ºF (16-204ºC)
Mustang Pony® Probe Maintains Sample Gas 98ºF (37ºC)
Cabinet Construction Hotpressed Glass Fiber Reinforced Polyester (GRP) or Stainless Steel
Heating Components 80 watt self-limiting block heater
Regulator Options MHR Single Stage Regulator
MJTHR Multi-Stage Regulator
Input Supply Voltage 115 VAC
240 VAC
24 VDC
Maximum Allowable Operating Pressure Options 2000 psig (138 BAR) @ 60ºF (16ºC)
(Liquid Block upstream of MHR - Standard Design)
3750 psig (259 BAR) @ 60ºF (16ºC)
(Liquid Block downstream of MHR)
6000 psig (414 BAR) @ 60ºF (16ºC)
(Liquid Block downstream of MJTHR)

Literature