The Mustang® Portable Heated Sampling System (Model 2) installs into a pressurized pipeline to extract and regulate a gas sample with a Mustang® Joule Thomson Heated Regulator (MJTHR), prior to reaching a portable analyzer.

The Portable Insertion Probe (PIP) installs directly into the pipeline, through a 1/2” or 3/4” full opening valve, utilizing a pressure balance technique. The MJTHR employs a 4‐stage pressure regulation, with a ratiocontrolled multi‐piston design, counteracting the Joule Thomson cooling effect .

The Mustang® Portable Heated Sampling System preserves the sample’s integrity from the extraction point to the analyzer.

  • Analytically Accurate® Technology
  • Analysis at sample point
  • Compact and portable
  • Low power requirement
  • Powered from truck inverter
  • Preserves gas sample integrity

 

Maximum Allowable Working Pressure6000 psig (414 bar) specify desired pressure when ordering
Maximum Recommended Flow Rate5 L/min
Outlet Pressure Range0-10, 0-25, 0-50, 0-100, 0-250, or 0-500 psig
(0-0.69, 0-1.72, 0-3.45, 0-6.89, 0-17.24, or 0-34.47 bar)
Probe Insertion DepthL: 0”-11”
Installation Valve Requirement1/2” or 3/4” NPT
Electrical Enclosure ClassificationClass 1, Div 1 & 2, Groups B, C, D
Power Rating Options120 VAC, 200 Watts, 50/60 Hz, ± 10%
208 VAC, 200 Watts, 50/60 Hz, ± 10%
230 VAC, 200 Watts, 50/60 Hz, ± 10%
24 VDC, 140 Watts
Wetted MaterialsMachined parts: 316 stainless steel/NACE compliant